Descargar Imprimir esta página

GE UVW8364 Manual Del Propietario Y Instalación página 12

Campanas de cocina con ventilación con extractor quietboost
Ocultar thumbs Ver también para UVW8364:

Publicidad

Idiomas disponibles

Idiomas disponibles

DUCT COVER REQUIREMENTS
Duct Cover Kit must be purchased separately. We
recommend that the vent hood and duct cover
(if used) be on site before final framing and wall
finishing. This will help to accurately locate studs,
ductwork, and electrical service.
• Duct cover accessory comes with a lower and
upper duct cover and installation hardware.
• The installation hardware includes mounting
brackets to secure duct covers to the wall.
• When not recirculating, holes can be hidden by
turning the upper duct cover upside-down.
• For ceiling installations up to 10' 8", use the 10'
High Ceiling Duct Cover kit CX10DC9SPSS.
• For higher ceiling installations up to 12' 8", use the
12' High Ceiling Duct Cover kit CX12DC9SPSS.
• See the next page for duct cover installation height
information.
12
Installation Preparation
INSTALLATION DIMENSIONS
The hood duct covers can be adjusted for different
ceiling heights depending on the distance between
the bottom of the hood and the cooktop (distance
X). See Installation Height Table on the next page.
5" Min
25" Max
Lower Duct Cover
19-1/2"
10"
Required Min & Recommended Max Ceiling
Height Examples for 10' Duct Cover Kit (Vented)
Electric
Gas
X
X = 24"
X = 30"
Min Y = 7' 6"
Min Y = 8' 2"
Max Y = 9' 2"
Max Y = 9' 10"
X = Distance from hood to cooktop. (Varies
depending on the installation) Required 24"
minimum over electric range or 30" minimum over
gas range. The recommended maximum is 36".
Typical Range
36" or
38"
NOTE: 36" for typical
electric range and 38" for
gas range.
Upper Duct
Cover
Y
X = 36"
Min Y = 8' 8"
Max Y = 10' 4"
49-2000708 Rev. 5

Publicidad

loading

Este manual también es adecuado para:

Uvw8304Uvw8364spssUvw8304spss