OPERATION
Controls
The hood is operated using the slide controls
under the bottom of the hood.
The light switch turns the lamps on and off.
The blower
switch:
makes it possible to
select the motor operating speed.
Position O:motor off.
The pilot lamp lights up whenever the blower
is on.
HEAT SENTRY
TM
Your
hood
is equipped
with
a HEAT
SENTRY
TM
thermostat.
This thermostat is a
device that will turn on or speed up the blower
if it senses excessive heat above
the cooking surface.
1) if blower is OFF - it turns blower ON to
HiGH speed.
2) if blower is ON at a lower speed setting -
it turns blower up to HiGH speed.
When the temperature level drops to normal,
the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat
can start
the blower even if the hood is turned OFF,
When this occurs,
it is impossible
to turn
the blower OFF with its switch,
If you must
stop the blower,
do it from
the main
electrical
panel,
LIGHT BULBS
This range hood requires
two light bulbs
(included); max 40W, 120V, E12, Type B or
Type T8 bulb.
ALWAYS SWITCH OFF THE ELECTRICITY
SUPPLY
BEFORE
CARRYING
OUT ANY
OPERATIONS
ON THE APPLIANCE.
To change bulbs:
1. Remove the screw securing the light fitting.
2. Pull down lens to remove.
3. Replace with light bulbs of the same type.
CAUTION: BULB MAY BE HOT!
LIGHT
SWITCH
BLOWER
SWITCH
PILOT
fig.14
i
fig.15
lO

Publicidad