Commander
Speed Controller System
Instructions
The Commander ® Pro Variable Speed Controller is a dependable
water system Variable Frequency Drive (VFD) that uses custom
programming to enhance the performance of submersible pumps .
When applied correctly to three phase motor driven pumps, the
drive eliminates pressure cycling associated with conventional
pressure switch controlled water pumping systems and provides
a constant output pressure .
Key features of the drive controller include:
•
Can use either a pressure switch (no snap action) or a
4-20mA transducer as the pressure control . At initial power
up, the controller detects whether a switch or transducer is
connected and automatically sets the control choice .
•
Constant water pressure with a wide range of settings (30-
80 psi) (Note: The maximum obtainable system pressure is
limited by the performance of the pump installed)
•
Smaller pressure tank can be used
•
Fits the pump to the application – pump speed is controlled
to provide the optimum performance without overloading the
motor
•
No in-rush (power-on transient) current
•
Low motor start-up current (soft-starting)
•
Active Power Factor Correction minimizes input RMS current
•
Protection features
OWNER INFORMATION
System Model Number
Pump Model / Date Code
Pump Serial Number (Silver Label)
Motor Model / Date Code
Motor Serial Number (Silver Label)
Controller Model / Date Code
Dealer
Address
Install Date
Pro Variable
®
DESCRIPTIONS AND FEATURES
HELP LINE: 800-742-5044
Flint & Walling © Copyright 2022. All rights reserved.
– Dry run conditions – using intelligent load monitoring (see
Page 7)
– Bound pump – with auto-reversing torque
– High voltage / lightning surge
– Low line voltage
– Short circuit
INCLUDED ITEMS:
A .
Controller Unit
B .
Pressure switch or Transducer
C . Switch or Transducer Cable
D . Installation Manual
E .
Small Screwdriver
F .
Warranty Card
G . Switch Adjustment Tool (VS Systems only)
Note: To change the display language, hold down the UP and
ESCAPE keys at the same time .
Note to Canada residents: A gallon refers to a US standard gallon
(3 .78 liters) .
TABLE OF CONTENTS
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Piping & General Information . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Controller Location Selection . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Controller Installation / Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Start-up Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
System Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9