Input from
Voltage
Power
Frequency
Source
Current (max)
(single
Power Factor
phase)
Voltage
Frequency Range
Output to
Current Factory
Motor (three-
Programmed
phase)
Current (max)
Factory preset
Pressure
Setting
Adjustment range
Temperature (at 230
Operating
VAC input)
Conditions
Relative Humidity
Controller
NEMA 3R (Indoor/
Size
Outdoor)
Weight
Minimum generator sizing
DRIVE SPECIFICATIONS
TVS/VS15
180 -264 AC
180 -264 AC
48 - 62 Hz, 57 Hz minimum when powered by generator
14 .5 Amps RMS 1ø
19 Amps RMS 1ø
1 .0 (constant)
1 .0 (constant)
Adjusts with Frequency
Adjusts with Frequency
5 .9 amps (RMS, each
8 .1 amps (RMS, each
phase)
phase)
6 .5 amps (RMS, each
8 .5 amps (RMS, each
phase)
phase)
17" H x 9 .25" W x 5 .25" D
4 .8kW
Flint & Walling © Copyright 2022. All rights reserved.
TVS/VS20
TVS/VS30
180 -264 AC
23 Amps RMS 1ø
1 .0 (constant)
Adjusts with Frequency
30 - 80 Hz
10 .9 amps (RMS, each
phase)
10 .9 amps (RMS, each
phase)
50 PSI
30 - 80 PSI switch / 15 - 80 PSI transducer
-20° to 50°C (-4° to 125°F)
Max 95% Non-condensing
19 lbs .
8 .0kW
13
TVS50
180 -264 AC
36 Amps RMS 1ø
1 .0 (constant)
Adjusts with Frequency
18 .0 amps (RMS, each
phase)
18 .0 amps (RMS, each
phase)
19" H X 9 .75" W X 5 .25"
D
25 lbs .
10 .0kW
15 .7kW