IIN THE EXTRACTION MODE:
a- Fit the non-return backflow flaps (C) over the round outlet (6) on top of the canopy while pressing
down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connec-
tions with appropriate clamping rings or adhesive tape Fig. 9.
b- Make the electrical connection of the motor as described in the section titled ELECTRICAL. Fig. 7.
c- Place the canopy under the motor housing and fix it with the screws provided as illustrated in Fig. 10.
Attention: 2 persons are necessary to secure this operation..
d- Fit the metal grease filters and close the deflector
IN THE RECIRCULATION MODE:
a- To carry out an inlet for recycling air in the kitchen Fig.11.
b- Connect the ducting 150mm (6 INS) not provided between motors (6) and the recirculation spigot and
secure the connections with appropriate clamping rings or adhesive tape Fig. 12.
c- Make the electrical connection of the motor as described in the section titled ELECTRICAL.Fig. 7.
d- Place the canopy under the motor housing and fix it with the crews provided as illustrated in Fig. 10.
Attention: 2 persons are necessary to secure this operation.
e- Fit the charcoal filter Fig. 13.
f- Fit the metal grease filters and close the deflector.
• CLIPPAGE ON THE FALSE CEILING
2) Mark the centre of the cooking appliance onto the ceiling with a plumb line. Draw the horizontal axes
(a1;a2) running parallel to the stove top onto the ceiling as illustrated Fig. 1.
3) To carry out the cutting of embedding in the suspended ceiling Fig 2a.
4) To remove the lighting front panel Fig. 15.
5) To unscrew the screws of the clips according to the thickness of the false ceiling Fig. 16. When fixing
the cooker hood to a plasterboard ceiling ensure it is reinforced as illustrated in Fig. 17. For the false ceil-
ing in MDF of 18 mm, 4 holds of compensation (2 mm thickness) are provided with the hood.
6) Open the deflector Fig. 6 (12).
7) To remove the metal filters.
IN THE EXTRACTION MODE:
a- Fit the non-return backflow flaps (C) over the round outlet (6) on top of the canopy while pressing
down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connec-
tions with appropriate clamping rings or adhesive tape Fig. 9.
b- Make the electrical connection of the motor as described in the section titled ELECTRICAL. Fig. 7.
c- Place the canopy under the motor housing and fix it with the screws provided as illustrated in Fig. 10
or clip the hood on the false ceiling Fig. 15, to tighten the screws Fig. 16 and to fit back the lighing front
panel.
Attention: 2 persons are necessary to secure this operation..
d- Fit the metal grease filters and close the deflector.
IN THE RECIRCULATION MODE:
a- To carry out an inlet for recycling air in the kitchen Fig.11.
b- Connect the ducting 150mm (6 INS) not provided between motors (6) and the recirculation spigot and
secure the connections with appropriate clamping rings or adhesive tape Fig. 12.
c- Make the electrical connection of the motor as described in the section titled ELECTRICAL. Fig. 7.
d- Place the canopy under the motor housing and fix it with the screws provided as illustrated in Fig. 10
or clip the hood on the false ceiling Fig. 15, to tighten the screws Fig. 16 and to fit back the lighing front
panel.
Attention: 2 persons are necessary to secure this operation.
e- Fit the charcoal filter Fig. 13.
f- Fit the metal grease filters and close the deflector.
GB