EN
4 - PRODUCT INSTALLATION
4.1 - Electrical connections
WARNING - Before making the connections, ensure that the control unit is not powered up.
MOTOR CONNECTOR
Power supply connection terminal board
L1
Motor live
COM
Motor common
L2
Motor live
COND
Motor capacitor
MOTOR LIMIT SWITCH CONNECTION
LS1
Limit switch 1 input
COM
Limit switch common
LS2
Limit switch 2 input
COND
L
N
1
2
GND
12/24
_
AC/DC
TX
PH2
18
FUSE 2
L1
COM
L2
1 2
3 4
GND
12/24
COM OUT
_
AC/DC
NC
RX
POWER SUPPLY CONNECTOR
L
Power supply live 230 Vac (120 Vac) 50-60 Hz
N
Power supply neutral 230 Vac (120 Vac) 50-60 Hz
COM Vac Common of the "CR" and "FLASH" outputs
CR
Courtesy light, 230 Vac (120 Vac) 100 W, output control-
lable also via radio ON-OFF command (radio channel 4
selecting fC.y. = 2, tC.y. = 0 )
FLASH
Flashing light, 230 Vac (120 Vac) 40 W
DIP SWITCH
Set on "ON" to disable inputs EDGE, PH2, PH1, STOP.
Eliminates the need to bridge the terminal board inputs.
WARNING - with the dip switch ON, the safety
devices are disabled
MENU
UP
DOWN
SBS
OUTPUT
24 Vdc
2
3 4
1
1 2
GND
12/24
GND
12/24
COM OUT
_
_
AC/DC
AC/DC
TX
RX
PH1
SHIELD
ANT
NC