4. Slide the first rubber float rod stop down the
float rod to about 8-in from the top of the float
rod.
5. Slide the float rod through the hole in the pump
switch.
6. Slide the second rubber float rod stop on to the
top of the float rod above the switch.
With rubber float rod stops in this position, the
pump will turn on at approximately 10 - 12-in
and off at 2-1/2-in.
WARNING: Risk of Flooding. Be sure that the float
rod is vertical and can move up and down freely. If
the float cannot move freely, the pump may not run.
6
© 2023. All rights reserved.
4
Approximately
8 in.
1st Float stop
Float rod
5
Pump switch
Float rod
6
2nd Float stop
1st Float stop
Float rod