LED Lighting Element 170AP
Electric installations
Bear in mind local electrical codes for switch box location.
The light shall always be connected via a safety transformer 12V AC of toirodal core-type (see table) to ensure correct operation
and maximum life. If more than one RGB light are installed, they shall be connected to the same transformer and via a common
power switch for synchronization, see Diagram.
The transformer's power shall be greater than the total value of all lights, please refer to the table below.
Supplied cable shall always be used for the engagement of the light.
If the light's external cable insulation or the inner conductor is damaged, it shall be replaced by a service technician or other
qualified person.
OBS! The lights should be completely covered by the water before they come on.
Recommendations
Wiring instructions Setup 1
Preferable when PLP PEM/PLP-REM 300 is used.
For new installations
Each lamp is connected to the transformer by a separate cable
TR1 150W alt. 350W
L1
IN
230V AC
N
The colour of the light
4m cable included in lamp package
Separate cable ( not included )
RGB - red/green/blue
8
The calculations of the cable lengths are made in relation to the maximum voltage drop in the electrical cables.
Circuit diagram
Example 1: WW/CW Lamp
TR1 150W (alt. 350W)
TR1 150W alt. 350W
L1
IN
IN
230V AC
230V AC
N
Cable length and cross-section, see table
OUT
LA1
12V AC
75W
Maximum cable lenght / Cable section
LA2
75W
!
1.5 mm
2.5 mm
2
Always use a toroïdal transformer
2
6 m
10 m
OUT
LA1
OUT
Lamp 1
12V AC
12V AC
60W
alt.
LA2
Lamp 2
60W
LA3
Lamp 3
60W
Wiring instructions Setup 1
For new installations
Each lamp is connected to the transformer by a separate cable
8
4.0 mm
6.0 mm
10.0 mm
2
2
16 m
25 m
Example 2: RGB Lamp
TR1 150W (alt. 350W)
TR1 150W alt. 350W
L1
IN
IN
230V AC
230V AC
N
TR1 150W alt. 350W
L1
IN
230V AC
N
E10084-0
2018-12-18 ASA
8
ENGLISH
Cable included
4m cable included in lamp package
Separate cable not included
Separate cable ( not included )
Transformer power [VA]
2
42 m
82
OUT
OUT
LA1
Lamp 1
12V AC
12V AC
75W
alt.
LA2
Lamp 2
75W
OUT
LA1
12V AC
60W
LA2
60W
LA3
60W
!
Always use a tor