66
BatteryPRO | E-HEALTH Charge 20
Multi language digital user manual
Troubleshooting - Warning Code Form
Status code
012200 → 012214
012223 → 012232
012241 → 012244
012251
Conditions
Abnormal input voltage
Abnormal environment or
devices temperature
External network dis-
connected
Emergency switch is
pressed
Troubleshooting methods
1.
Charging can be enabled after electrical grid supply
regularly
2.
Please check the input power or turn off and restart
the charger
3.
Please contact your dealer
1.
Keep the air flow inlet and outlet clear or remove
heat sources, charging will be enabled after cooling
down
2.
Maloperation of over temperature protection or de-
vices over temperature. Please contact your dealer
1.
Code scanning or app authorize application are un-
available for the moment, please change to RFID or
other authorizations
2.
Please contact network management staff for net-
work inspection
1.
Please release the emergency switch by rotating,
charging will be enabled after warning code is re-
moved. (Meanwhile, if it shows service page, please
rotating back the switch, turn off and restart the
charger)
2.
Please contact your dealer or turn off and restart the
charger