70
BatteryPRO | E-HEALTH Charge 20
Multi language digital user manual
(033-XXX) Troubleshooting-Message code from charger network
033-XXX contains messages from charger control server which is running intelligent remote control.
Please follow the remote procedure or contact management staff to arrange for charging.
Status code
033900
033901
033902
033903
033904
033905
Conditions
Back-End disconnected
for the moment
Charging started by remo-
te control
Charging stopped by
remote control
Restart by remote control
Troubleshooting methods
1.
Code scanning and app authorization is unavail-
able for the moment, please change to RFID or
others authorization
2.
Please contact management staff to check Back-
End server connectivity
3.
If the connection cannot be restored after router or
AP restart, please restart the main/ sub cabinets
4.
If the connection cannot be restored after main/
sub cabinet restart, please turn off the whole char-
ger and restart
5.
Please contact your dealer
1.
Remote authorization passed, please plug in the
charging cable for charging
2.
Contact management staff for further instructions
1.
Charging meets setup time, Watt-Hour or amount,
charging terminated by remote control
2.
Contact management staff for further instructions
1.
Charger reset and maintain process by remote con-
trol, charging terminated
2.