In manual operation the sensor fields are deactivated. The pump then runs
until the pump is disconnected from the mains or another operating mode
is selected.
v Keep the sensor fields
ß
S6
all LED's has acknowledged the input.
All LEDs will light up and within 5 seconds all the LEDs will switch off
one after the other. The pump starts.
During these 5 seconds the pump should be placed in the water. A start
will only take place if the pump detects water. If this is not the case, the
countdown is repeated up to three times.
If you need more time to put the pump into the water, please disconnect
the pump from the power supply. The countdown will continue after the
sensor is plugged in again.
The manual operation remains active even after disconnecting the power
supply.
To stop manual operation, disconnect the pump from the mains and take
it out of the water. Connect the pump to the power supply again and keep
sensor field
ß
pressed until it is acknowledged by double flashing of all
S9
LEDs. Now you are again in automatic mode.
Only operate the manual mode under supervision.
Time-limited manual operation:
In time-limited manual operation, the sensor fields are deactivated for
10 minutes. The pump then runs for 10 minutes and then switches off
automatically.
v Keep both sensor fields
ß
S7
all LED's has acknowledged the input.
All LEDs will light up and within 10 seconds all LEDs will switch off one
after the other. The pump starts.
After 10 minutes the pump automatically switches back to automatic
operation.
After disconnecting the power supply, the pump auto matically switches
back to automatic operation.
To return to the automatic mode again, push and hold the 2 sensor
fields
ß
and
ß
simultaneously until the double flashing of all LEDs has
S7
S8
acknowledged the input.
To change the function mode:
The pump can be switched between clear water and dirty water.
To do this, the pedestal is extended or retracted.
To extend the pedestal (dirty water) [ Fig. O2 – O5 ]:
1. Take the pump out of the water [ Fig. O2 ].
2. Lift up the pump and push the button
extended [ Fig. O3 ].
3. If the pedestal does not extend completely, stand with your feet on
the wings of the stand and pull the pump upwards [ Fig. O4 ].
4. Release the button
(6)
again before you put the pump back down
[ Fig. O5 ].
The max. delivery rate is achieved with the pedestal extended.
The pedestal is correctly locked in position when the button is fully
extended. If the button is not fully extended, repeat the process.
To retract the pedestal (clear water) [ Fig. O6 – O9 ]:
1. Take the pump out of the water [ Fig. O6 ].
2. Place the pump on a firm surface and push the button
3. Push the pump down until the pedestal
the handle [ Fig. O8 ].
4. To lock, push the pump down until the button
[ Fig. O9 ].
5. When submerging the pump again, make sure that it is on a firm
surface so that it cannot get stuck (e. g. foil).
The minimum residual water depth (see 7. TECHNICAL DATA) is only
achieved with the pedestal retracted in manual mode.
For best possible suction, we recommend switching to clear water mode
when the water level has reached the turquoise ring.
4. MAINTENANCE
DANGER! Risk of physical injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before you maintain
the product.
GAR_09049-20.960.04_2024-01-09.indd 11
GAR_09049-20.960.04_2024-01-09.indd 11
and
ß
pushed until the double flashing of
S8
and
ß
pushed until the double flashing of
S8
(6)
until the pedestal
(7)
(6)
[ Fig. O7 ].
(7)
is fully retracted and release
(6)
is fully extended again
To clean the pump:
DANGER! Risk of physical injury!
Risk of injury and risk of damage to the product.
v Do not clean the product with a water jet (in particular
high-pressure water jet).
v Do not clean with chemicals including petrol or solvents.
Some can destroy critical plastic parts.
v Clean the surface of the pump with a damp cloth.
To flush the pump:
After pumping water containing chlorine, detergents or heavily soiled
water, the pump must be flushed.
1. Pump lukewarm water (max. 35 °C), possibly adding a mild cleaning
agent (e. g. detergent) until the pumped water runs clear.
2. Flush the button if the water is very dirty.
3. Remove residuals according to the waste disposal laws applicable in
your area.
To clean the button [ Fig. M1 ]:
If the button gets stuck due to dirt, it can be cleaned.
1. Push in the two lockings
2. Pull off the button
(6)
3. Clean the button
water.
4. Reassemble the button
5. STORAGE
To put into storage:
The pump is not frost-proof!
The product must be stored away from children.
1. Disconnect the pump from the mains.
2. Turn the pump upside down until no more water runs out.
3. Clean the pump (see 4. MAINTENANCE).
4. Store the pump in a dry, enclosed and frost-free place.
Disposal:
is fully
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household
waste. It must be disposed of in line with local environmental
regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.
6. TROUBLESHOOTING
DANGER! Risk of physical injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before you trouble-
shoot the product.
To clean the pedestal and the impeller [ Fig. T1 / T2 ]:
If the pedestal cannot be changed according to the chapter
3. OPERATION To change the function mode, the pedestal must
be cleaned.
1. Unscrew the 4 Phillips screws
2. Pull the suction base
3. Unscrew the 4 Phillips screws
4. Pull the pedestal
(7)
5. Clean the pedestal
(the warranty does not become void as a result of this maintenance
work).
6. Clean the sealings
7. Reassemble the pedestal
Make sure that the 4 springs
(7)
pedestal
.
(13)
.
(6)
.
(13)
, the lockings
and the handle under running
(6)
in reverse order.
(8)
.
(9)
off the pump.
(10)
.
off the suction base
(9)
.
(7)
(9)
, the suction base
and the impeller
(14)
carefully to avoid damage and leakage.
(7)
(9)
and the suction base
in reverse order.
(12)
are fitted on the domes
(11)
(15)
of the
11