Switching the battery power supply on or off
Battery power on (default)
1 2 3 4 5
O
N
To turn the battery on activate the DIP switch 6.
To turn the battery off deactivate the DIP switch 6.
NOTE Turning the battery on or off with the DIP switch 6 has the same effect as using the On/Off switch
but using the DIP switch 6 provides immediate visual feedback from the battery about its status.
10 Connecting batteries in parallel
NOTE To increase the ampere-hour (Ah) capacity multiple batteries can be connected in parallel. Up to
16 devices can be connected to the N-BUS network.
Connect the batteries in the following order:
1.
Open the connection box (1) of the batteries.