LED indications
LED indication
Green constantly lit
Green flashing
Blue flashing
Purple flashing
Red flashing
Orange flashing
Orange constantly lit
Off
Charging
When charging the battery with an external charger, observe the following guidelines:
• For best results use chargers intended for charging LiFePO4 batteries. If you do not have such a charger, you
can use lead-acid battery chargers.
• The charger must not perform any desulfation action.
• When using a configurable charger set the contant current/constant voltage (CC/CV) option with the follow-
ing values:
Set the end of charge voltage to 14.4 V.
Set the recommended maximum charging current for the battery.
• The maximum charging voltage should not exceed 14.5 V. If the charging voltage is 14.7 V ... 16 V the internal
battery management system (BMS) will limit the charge.
• If during charging the temperature raises above the permissible range, the internal battery management sys-
tem (BMS) will limit the charge to preserve battery life.
• At the end of the charging the charger can be disconnected, be turned off, or kept connected at float voltage.
TLB100F, TLB120F and TLB150F: When the battery is being charged at temperatures below 0 °C, the cell heating
system is activated. The cell heating system uses the charger's energy to power itself. Once the ideal charging tem-
perature is reached, the heating is switched off and the charging begins.
Discharge
The internal battery management system (BMS) protects the electronic system and the battery cells. It supports a
continuous current of 135 A. However, it is possible to use higher currents for a limited time, in accordance with the
following values.
Discharging current
150 A
14
Description
Battery starting up. No voltage is present at the terminals.
Battery active. Voltage is present at the terminals.
Battery powering down. Bluetooth® active. No voltage is present at the terminals.
Battery powering down. Bluetooth® not active. No voltage is present at the terminals.
Battery alarm. No voltage is present at the terminals.
Temperature range limit reached. Voltage is present at the terminals.
Firmware update.
Battery inactive. No voltage is present at the terminals.
TLB100/TLB100F
15 min
Maximum discharging time
TLB120/TLB120F
20 min
TLB150/TLB150F
25 min