5. Commissioning and operation
5.9 Expansion loops
Expansion loops should be designed to account for maximum tube movement from start
up position to operating temperature. Loops should be designed in accordance with
allowable space available. Examples of expansion loops are S-loop, multiple coil, single
coil and spiral loop.
S-loop
Single coil
5.10
Exiting the furnace
CAUTION!
Damage to the MIMS cable through flame impingement
Exposure to direct flame could inhibit sensor performance.
Ensure the cable does not pass through direct flame. The sensor should
exit the furnace as per installation requirements/best practices for
routing.
MIMS cable must follow best practices for routing.
5.10.1
Fixed exit
Assemble the process neck tube as per the installation.
Install and tighten compression fitting to manufacturer's specifications.
CAUTION!
Damage to the cable
The sensor/transition may be damaged if tightened near the transition
region
Do not place compression fitting on the transition.
WIKA operating instructions model TC59-E (eTEFRACTO-PAD)