Descargar Imprimir esta página

WIKA Gayesco TC59-E Manual De Instrucciones página 25

Conjunto termopar tubeskin

Publicidad

Idiomas disponibles

Idiomas disponibles

9. Specifications
Measuring element
Type K
Type J
Type N
Validity limits of the class accuracy per ASTM-E230
Type K
Type J
Type N
Colour code of cable
IEC 60584-3
Thermocouple type
K
J
N
ASTM E230
Thermocouple type
K
J
N
→ For detailed specifications for thermocouples, see IEC 60584-1 or ASTM E230 and
technical Information IN 00.23 at www.wika.com.
The table shows the temperature ranges listed in the respective standards, in which
the tolerance values (class accuracies) are valid. When using a compensating cable
or thermocouple cable, an additional measuring error must be considered. For the
tolerance value of thermocouples, a cold junction temperature of 0 °C [32 °F] has been
taken as the basis.
WIKA operating instructions model TC59-E (eTEFRACTO-PAD)
Class 2
Class 1
Class 2
Class 1
Class 2
Class 1
Standard
Special
Standard
Special
Standard
Special
Positive leg
Green
Black
Pink
Positive leg
Yellow
White
Orange
-40 ... +1,200 °C [-40 ... +2,192 °F]
-40 ... +1,000 °C [-40 ... +1,832 °F]
-40 ... +750 °C [-40 ... +1,382 °F]
-40 ... +750 °C [-40 ... +1,382 °F]
-40 ... +1,200 °C [-40 ... +2,192 °F]
-40 ... +1,000 °C [-40 ... +1,832 °F]
0 ... 1,260 °C [32 ... 2,300 °F]
0 ... 1,260 °C [32 ... 2,300 °F]
0 ... 760 °C [32 ... 1,400 °F]
0 ... 760 °C [32 ... 1,400 °F]
0 ... 1,260 °C [32 ... 2,300 °F]
0 ... 1,260 °C [32 ... 2,300 °F]
Negative leg
White
White
White
Negative leg
Red
Red
Red