AUTO RESTART OPERATION

This air conditioner is equipped with an automatic restarting function which allows the air conditioner to resume without the use of the
remote control under the operating settings in the event of a power shutdown. Operation resumes without warning three minutes after
power is restored.
INFORMATION
INFORMATION
The AUTO RESTART OPERATION is not set to work at factory shipment, and so it is necessary to set it to this function if
required.
HOW TO SET AUTO RESTART
To set the auto restart function, proceed as follows:
The power supply to the unit must be on. The function will not be set if the power is off.
To enable the auto restart function, hold down the RESET button for 3 seconds.
The air conditioner receives the setting and beeps 3 times. The system now restarts
automatically. The auto restart setting is activated.
(1) When the air conditioner is in stand-by (not running).
Hold down the RESET button for more than 3 seconds.
• The air conditioner starts to operate. The green indicator turns on.
• After about 3 seconds, the air conditioner beeps 3 times.
The green indicator flashes for 5 seconds.
• The air conditioner is operating.
If the air conditioner is not required to run at this time, push the RESET button
again or use the remote control to stop the air conditioner.
(2) When the air conditioner is operating.
Hold down the RESET button for more than 3 seconds.
• The air conditioner stops operating. The green indicator turns off.
• 3 seconds after pushing the button, the air conditioner beeps 3 times.
The green indicator flashes for 5 seconds
• The air conditioner stops.
If you do not need the air conditioner to stop at this time, use the remote control to restart the air conditioner. During the
subsequent operation, the green indicator is turned on.
• The auto restart operation will not accept a command if timer operation with the remote control is activated.
• After restarting the air conditioner by the AUTO RESTART OPERATION, the louver swing (AUTO) operation does not resume.
HOW TO CANCEL AUTO RESTART
To cancel the auto restart operation, proceed as follows:
Repeat the setting procedure. The air conditioner receives the setting and beeps 3 times.
The air conditioner now needs to be manually restarted with the remote control after the main supply is turned off.
The auto restart setting is cancelled.
(1) When the air conditioner is in stand-by (not running).
Hold down the RESET button for more than 3 seconds.
• The air conditioner starts to operate.
The green indicator will turn on.
• After about 3 seconds, the air conditioner beeps 3 times.
• The air conditioner is operating.
If the air conditioner is not required to run at this time, push the RESET button
again or use remote control to stop the air conditioner.
(2) When the air conditioner is operating.
Hold down the RESET button for more than 3 seconds.
• The air conditioner stops operating.
The green indicator is turned off.
• After about 3 seconds, the air conditioner beeps 3 times.
• The air conditioner stops.
If you do not need the air conditioner to stop at this time, use the remote control to
restart the air conditioner.
During subsequent operation, the green indicator is turned on.
15
www.ilmalämpöpumput.com
RESET button
RESET button