Installing the SHLX
INSULATION BLANKETS
WARNING: If
local codes require
external application of
insulation blanket kits
the manufacturer's
instructions included
with the kit must be
carefully followed.
Insulation blankets,
available to the general
public, for external use
on gas water heaters
PIPE INSTALLATION
Inlet Pipe and Outlet Pipe Installation
Use pressure resistant pipe to connect the inlet and
outlet water pipes of the water heater and the local
water pipe (Make sure to place the rubber ring).
Before connecting the inlet water pipe, flush the
inside of the pipe.
Hot Water
Outlet
Washer
Nut
Hot Water Pipe
DURING INSTALLATION OF THIS WATER HEATER:
DO check inlet gas pressure to ensure that it is within the range specified on the rating plate.
DO provide adequate air for combustion and ventilation as discussed in the Use and Care Manual and
the National Gas Code (CAN/CGA B in 149 Canada).
DO maintain proper clearances to combustibles as specified by applicable code.
DO ensure that the fuel terminal location complies with the guidelines found in the Use and Care
Manual and National Fuel Gas Code (CAN/CGA B 149 in Canada).
DO NOT block or restrict air intake opening located on the back side of the water heater.
DO NOT remove the front cover unless absolutely necessary. This should only be done after being
examined by a qualified service technician.
DO NOT install this product where standing water may occur.
28
Support: Support.Eccotemp.com
are not necessary. The purpose of
an insulation blanket is to reduce
the standby heat loss encountered
with storage tank heaters. This
water heater does not store water
making an insulation blanket
unnecessary.
The manufacturer's warranty does
not cover any damage or defect
caused by installation, attachment
or use of any type of energy saving,
Or other unapproved devices
(other than those authorized by
Water
Gas Inlet
Inlet
Washer
Nut
Cold Water Pipe
PLEASE NOTE: SHLX IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO
CHANGE WITHOUT NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.
the manufacturer) into, onto or in
conjunction with the water heater.
The use of unauthorized energy
saving devices may shorten the life of
the water heater and may endanger
life and property.
The manufacturer disclaims any
responsibility for such loss or injury
resulting from the use of such
unauthorized devices.
Hot and Cold Pipe Insulation Installation
For increased energy efficiency,use pipe
insulation. Please install the insulation,
according to the illustrations above, making
sure to insulate all the way to the top. Do not
cover any drain or pressure valve(s).
Outlet Pipe
Hot Water
NOTICE: The hot and cold pipes should be insulated
as shown help to provide additional freeze protection
Shop Online: www.Eccotemp.com
Check Valve
or Backflow
Gas Inlet
Preventer
Inlet Pipe
Cold Water
Phone: 866-356-1992