LOCATION REQUIREMENTS
Consider all of the following when selecting an
installation location for the water softener.
= Do not locate the water softener where freezing
temperatures occur. Do not attempt to treat water
over 120ºF. Freezing temperatures or hot water
damage voids the warranty.
= To condition all water in the home, install the water
softener close to the water supply inlet, and
upstream of all other plumbing connections, except
outside water pipes. Outside faucets should remain
on hard water to avoid wasting conditioned water
and salt.
= A nearby drain is needed to carry away
regeneration discharge (drain) water. Use a floor
drain, laundry tub, sump, standpipe, or other
options (check your local codes). See "Air Gap
Requirements" and "Valve Drain Requirements"
sections.
= The water softener works on 24 V DC electrical
power, supplied by a direct plug-in power supply
(included). Provide nearby a 120 V, 60 Hz electrical
outlet in accordance with NEC and local codes.
= Always install the water softener between the water
inlet and water heater. Any other installed water
conditioning equipment should be installed between
the water inlet and water softener (See Figure 3
below).
= Avoid installing in direct sunlight. Excessive sun
heat may cause distortion or other damage to
non-metallic parts.
THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
Cold Water
to House
Hot Water
to House
Water
Heater
Installation Requirements
Untreated Water to
Outside Faucets
Optional
Sediment
Water
Softener
PLUMBING CODES
All plumbing must be completed in accordance with
national, state, and local plumbing codes.
In the state of Massachusetts: The Commonwealth
of Massachusetts plumbing code 248-CMR shall
be adhered to. A licensed plumber shall be used
for this installation.
AIR GAP REQUIREMENTS
A drain is needed for regeneration water (See Figure
2). A floor drain, close to the water softener, is pre-
ferred. A laundry tub, standpipe, etc. are other drain
options. Secure valve drain hose in place. Leave an
air gap of 1-1/2" between the end of the hose and the
drain. This gap is needed to prevent the backflow of
sewer water into the water softener. Do not put the
end of the drain hose into the drain.
1-1/2"
air gap
FLOOR DRAIN
Pressure
Tank
Filter
6
Drain
Hose
Drain
Hose
1-1/2"
air gap
STANDPIPE
LAUNDRY TUB
City Water Supply
OR
Well Water Supply
Well
Pump
Drain
Hose
1-1/2"
air gap
FIG. 2
FIG. 3