1. INTRODUCTION
Th is instruction manual has been draft ed
in accordance with the requirements of the
Machinery Directive 2006/42/ CE. Th e ins-
truction manual is an integral part of the
lift ing tower to be consulted before, during
and aft er tower's start-up, likewise whenever
deemed necessary, respecting the contents
for each and all the parts thereof.
Th is is the only way to achieve the basic ob-
jectives established in the manual's base such
as preventing accident risks and the maxi-
mum possible optimisation for the lift ing
tower features.
Th is manual has taken extreme care regar-
ding safety and accident prevention at work
while using the machine, highlighting infor-
mation of particular interest to the user.
ATTENTION: BEFORE TO USING THE
LIFTING TOWER,
READ THIS MANUAL CAREFULLY
12 12
2. GENERAL DATA
2.1. Technical Data:
Name: LIFTING TOWER
Model: AT-04B
Technical characteristics:
Maximum height: 5,00m.
Minimum height: 1,59m.
Maximum load: 200kg.
Minimum load: 25kg.
Material: Aluminium AL Si 6082 / T6.
Workspace: 1,45 x 1,49m.
Closed base area: 0,38 x 0,48m.
Weight: 93kg.
Winch: 900kg maximum load with automa-
tic load retention brake.
Cable: Galvanized steel under EN 12385-4.
Cable maximum load: 2870kg.
Cable torsion resistance: 1.770N/mm².
Cable diameter: 6mm.
Cable composition: 7x19+0.
Fixation of tower sections to working height
with safety pins.
Leg anchorage with safety pins.
Bubble level to adjust tower's vertical posi-
tion.
Equipment description:
Lift ing tower AT-04B has been designed to
vertically raise structures and lighting and
sound equipment to diff erent heights.
Tested by skilled personnel having passed all
the operating, maximum load and dimen-
sion inspections.
Company: FENIX Stage, S.L.U.
Address: Avda. de los Trabajadores, 24
Horno de Alcedo - 46026 - Valencia (Spain)
2.2. Applicable regulations
- Directiva de máquinas 2006/42/CE.
- DGUV Rule 115-002
- DGUV 17&18
- EN 12385-4:2008-06.
- DIN EN 10305-3:2010-05.