8.
Turn the power back on. If the module doesn't illuminate within 5 seconds, turn power off, carefully remove the module and
double check all wiring and replace. (Figure 7)
WARNING: DO NOT PLACE YOUR HAND UNDERNEATH SPRING CLIP DURING REMOVAL PROCESS.
SNAPPING OF THE CLIPS CAN CAUSE INJURIES TO THE HAND (Figure 8).
WARNING: DO NOT CONNECT MULTIPLE MODULES TO ONE DRIVER
WARNING: DO NOT OPEN THE MODULE INSIDE OF THE REMOTE DRIVER BOX - NO SERVICEABLE
TROUBLE SHOOTING GUIDE
If this fixture fails to operate properly, use the guide below to diagnose and correct the problem.
Verify that fixture is wired properly.
•
Verify that fixture is grounded correctly.
•
Verify that the line voltage at the fixture is correct.
•
If further assistance is required, contact: Technical Support at: (800) 705-SERV (7378).
This LED module does not require service or new bulbs to change.
The LED modules are compatible with several standard residential dimmers. A list of recommended dimmers can be found at
www.acuitybrands.com,keyword search WF2. Exclusion from this list does not mean a dimmer will not work in conjunction with the
led module. Consult the dimmer manufacturer regarding compatibility with LED Modules.