Note
The device must be switched off imme-
diately if a malfunction occurs (e.g. fil-
ter breakage). The malfunction must
be eliminated before switching the de-
vice on again.
Remove the blockage
Wand/stretch hose
Illustration K
Illustration L
Note
When inserting the stretch hose into
the stretch hose port, make sure that it
engages in place.
Stretch hose at vacuum nozzle
Illustration M
Roller brush/vacuum nozzle
Illustration N
Note
If necessary, remove the brush cover
(see "Cleaning the roller brush manual-
ly").
Error codes
E1
Suction volume too low, indicator light
flashes
1. Replace the fleece filter bag.
2. Remove blockages from the vacu-
um nozzle, wand and stretch hose.
E2
Turbine error, indicator light flashes
1. Switch off the device and wait 1 min-
ute. Switch the device back on.
2. If the fault occurs repeatedly, notify
customer service.
E3
Power transmission to roller brush in-
terrupted, indicator light flashes
1. Notify Customer Service.
E4
Temperature of the battery pack too
high, indicator light flashes
1. Reset the error by actuating the
main switch.
2. If the fault occurs repeatedly, re-
place the battery pack. Check the
removed battery pack according to
the manufacturer's operating in-
structions.
E5
Current consumption of the brush mo-
tor too high, indicator light flashes
1. Switching off the device and check
the roller brush for blocking objects
and remove these if present.
2. If the malfunction occurs repeatedly,
notify customer service.
Malfunction occurs during semi-auto-
matic brush cleaning
1. Switch off the device. Switch on the
device and let it run for 20 seconds in
roller brush mode. Operate the semi-
automatic brush cleaning again.
2. Repeat this process 2-3 times if nec-
essary.
3. If the malfunction occurs repeatedly,
notify customer service.
E6
Current consumption of the turbine too
high, indicator light flashes
1. Notify Customer Service.
E7
Turbine defective, indicator light flashes
1. Notify Customer Service.
E8
Current consumption of the battery
pack too high, indicator light flashes
1. Switch off the device. Reset the er-
ror by actuating the main switch.
2. If the fault occurs repeatedly, re-
place the battery pack. Check the
removed battery pack according to
the manufacturer's operating in-
structions.