Provide for a sampling point (sealed and easily removable) on the fume
connection for periodic checks on emissions.
Check the flue dataplate for safety distances that must be respected in the
presence of combustible materials and possibly the type of insulating material
to be used.
It is forbidden to connect the unit to a collective flue or to a flue shared with other
combustion units or hood exhausts.
It is forbidden to use the direct wall outlet or towards closed spaces and any
other form of outlet not envisaged by the regulations in force in the country of
installation.
EN
1
E
U
S
V
A
U
B
A
D
C
4
U
V
T
I
P
A73023890 - Rev 03 - 02/2024
a
Distance from combustible material (fume
duct plate)
b
Max. 4 m
c
Min. 3° slope
d
Distance from combustible material (unit
dataplate)
E
e
Backflow area
f
Air ducting
i
Inspection plug
p
Air inlet
s
Inspection door
t
T-piece with inspection plug
u
Insulation
v
Possible increase in diameter