Descargar Imprimir esta página

Ferroli LIRA SLIM PLUS Instrucción De Uso, Instalación Y Mantenimiento página 162

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Always keep the support surface of the pellet hopper door clean.
Frequently check the condition of the pellet door seal; in case of deterioration,
contact the authorized service center.
It is forbidden to remove or modify the pellet tank protection grid.
The bags of pellets must be placed at a safe distance from the unit.
8.
CLEANING
8.1
GENERAL INSTRUCTIONS
Cleaning the unit is very important to prevent: poor combustion, deposits of ash and
unburnt products in the brazier, as well as reduced heating efficiency.
Cleaning operations for all parts must be carried out with the unit electrically
disconnected and completely cold.
Clean the brazier regularly every time the unit is lit and/or whenever reloading
pellets.
Dispose of cleaning waste, respecting the applicable local regulations.
8.2
MAINTENANCE TABLE
The following summarizes the control and/or maintenance interventions useful for correct use and operation of the
unit, to be carried out by the USER and/or by an AUTHORIZED SERVICE CENTER.
Parts / Period
Type of cleaning
Brazier
Ash-pan compartment
Glass
Fume exchanger - baffle
Fume extractor - manifold
Glass - door seal
Pellet door seal
Safety valve
Pipe – flue connection
Electromechanical components
The seals of the pellet door, fire door, air intake manifold and the fume exhaust ensure
correct operation of the unit. These components must be periodically checked by the
user, if worn or damaged they must be replaced immediately by an authorized service
center.
162
1 day
2-3 days
1 month
user
user
user
cleaning
cleaning
cleaning
A73023890 - Rev 03 - 02/2024
LIRA SLIM PLUS
2 - 3 months
Maintenance performed by the
Technical Support Center
1 year
Maintenance performed
by the Technical Support
Center
EN

Publicidad

loading