Descargar Imprimir esta página

Ferroli LIRA SLIM PLUS Instrucción De Uso, Instalación Y Mantenimiento página 154

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6.1.1
Remote control battery type and replacement
The remote control is powered by a 3-volt CR2025 battery located in the lower part of the device and for its insertion
and possible replacement it is necessary to proceed as follows:
- o perate the lever indicated on the back of the remote control;
- p ull out the battery holder drawer and replace the battery (CR2025 3 Volt model), respecting the polarity;
- i nsert the drawer;
- c heck that it works properly with the unit operating.
Keep the remote control away from direct heat sources and water.
The remote control batteries must be replaced and disposed of separately in
appropriate containers in a safe manner in compliance with local environmental
regulations.
6.1.2
Turning on
Before turning on the unit, the following points need to be checked:
▪ make sure to have read and understood the manual;
▪ the hopper must be loaded with pellets with the door closed;
▪ the combustion chamber must be clean;
▪ the brazier must be completely free, clean of any combustion residues, complete with flame baffle and positioned
correctly in the brazier holder seat;
▪ check the hermetic closure of the fire door and possible pellet door.
At first lighting, remove all components that could burn from the insert firebox
and from the glass (instructions/label).
Any lightings done after long idle periods require complete cleaning of the
combustion chamber and the removal of any pellets left in the hopper, in being
damp fuel no longer suitable for combustion.
In the first hours of operation, fumes and odors may be generated due to the
normal heating process of the appliance without causing any problems. During
this process, which lasts for a short time and is limited to the first heating-
cooling cycles, it is recommended to ventilate the installation room well with the
appliance operating at maximum power for a short period of time.
When the unit is powered, the resident software version appears on the display and then the status of the same
which, in the case of first start-up, will be off (OFF).
To turn on, press the ON/OFF button for a few seconds, until "Ignition" appears on the display and the ON/OFF
LED flashes. In these conditions, the unit goes into pre-heating and the resistance (Igniter LED) and fume extractor
fan come on.
After a preset time the pellet loading phase begins. The phase is indicated by the message "Pellet Loading" on the
display and the ON/OFF LED flashing.
Pellet loading occurs with an ON/OFF auger cycle and ON time for a maximum time; if within this time the board
does not detect the flame, there will be a failed ignition error.
It is forbidden to use flammable liquids for lighting.
In case of continuous failed lighting, contact the Service Center.
154
A73023890 - Rev 03 - 02/2024
LIRA SLIM PLUS
EN

Publicidad

loading