ELECTRICAL CONNECTIONS
Risk of severe injury or death by electrical shock, or damage to system.
• Always disconnect the electrical power before touching the pump.
• A ground fault circuit interrupter (GFCI) is required.
• If the power cord is damaged, it must only be replaced by qualified personnel.
Changing the Voltage
This pump comes with a dual voltage motor (115 V/230 V) and is
factory set for 230 V. Ensure the voltage indicator matches the
voltage at the power source. Do not connect to voltage other
than that shown.
IMPORTANT: Ensure the motor is grounded and the motor
terminal is in place.
1. Disconnect the power supply to the pump.
2. Remove the cover from the motor terminal box.
3. To change the voltage to 115V, pull and rotate the dual volt-
age switch and set to "Low V" from the "High V" factory set-
ting.
4. To change the voltage on other models, press the black
voltage change device onto both terminals with the
white arrow directly aligned with the correct voltage on
the terminal board.
IMPORTANT: Do not move the white lead wires on L1
and L2.
5. Reassemble the terminal box cover.
ELECTRICAL CONNECTIONS
Specifications
230
230
Orange
Brown
115
230
115
115