2.
Follow the steps of
EN
WELDING THROUGHT BAR CODE
READING on page 15
the cooling time
is not stored: read the sticker and
wait for the time printed by the
manufacturer.
PRINTOUT AND USB CONNECTION
It is possible to download the
welding reports into a pen drive
(formatted FAT 16 or FAT 32) or print
them on a printer connected
through a serial adapter.
Select the "PRINTS & USB-CON"
mode and press OK ►.
Select your suitable option
Use ▲ and ▼ buttons to scroll the
options.
Connect
the
device
adapter.
Press OK ► to confirm.
Reports are available in pdf or
binary format. The latest format
requires an additional PC software
to read the data.
The
format
can
be
through the
OTHER FUNCTIONS' CODES below.
OTHER FUNCTIONS' CODES
FUNCTION
DATE/HOUR SETTING
LANGUAGE
CELSIUS - FAHRENHEIT 1110
CALIBRATION REPORT
to USB/PRINTER
If you do not delete the reports and
continue to use the machine, the last report will replace the first
one in the memory, then the second report will be replaced,
and so forth.
16
to
the
USB
Print last report
Print all reports
selected
CODE
FUNCTION
DELETE
STORED
1000
REPORTS
REPORT
FORMAT
1100
(PDF,PG2
OPTICAL
PEN
OR
SCANNER
1400
7.
ALARM CODES AND THEIR MEANING
error code is displayed. The interruption may jeopardize the
fitting to be welded. In no event shall Ritmo S.p.A be liable for
any direct, indirect, incidental, or consequential damages of
any whatsoever with respect to the use of pipes/ fittings
involved in the welding cycles resulting in error codes.
5 – POWER SOURCE VOLTAGE
Probable cause: Power source voltage out of range
Solution: check the power source and make sure it is suitable to
the machine features and requirements.
10 – POWER SOURCE FREQUENCY
Probable cause: Power source frequency out of the range
Solution: check the power source and make sure it is suitable to
the machine features and requirements.
15 – VOLTAGE ON THE WELDING LEADS IN STANDBY MODE
Probable cause: Hardware failure
Solution: contact an authorized service center.
20 –AMBIENT TEMPERATURE OUT OF THE RANGE
Probable cause: Ambient temperature is out of range
Solution: Protect the working site where the welding is taking
place in order to get a suitable ambient temperature.
25 – HARDWARE OVERHEATING
Probable cause: Fan not working or too many welding cycles
Solution: Check the fan status and wait till the machine has
cooled down.
30 – WELDING VOLTAGE OUT OF CONTROL
Probable cause: The power source is supplying an out-of-range
voltage.
Solution: check the power source and make sure it is suitable to
CODE
the machine features and requirements.
2110
35 e 40 –MACHINE OVERHEATED
1122
Probable cause: the machine overcomes its maximum working
temperature in the last welding
1111
Solution: Wait until the machine has cooled off.
45 – CURRENT EXCEEDS MAXIMUM LIMIT
Probable cause: The heating wires inside the coupler made a
short circuit
Probable cause: The coupler diameter is bigger than allowed
Solution: Repeat the welding with another coupler
50 – CURRENT BELOW MINIMUM VALUE
Probable cause: One or both welding cables were unplugged
during the welding
Solution: Reconnect the welding cables and repeat the
procedure
Probable cause: The heating wires inside the coupler are
interrupted
Solution: Repeat the welding with another coupler
Probable cause: The coupler is too small (the electrical
resistance is too high)
Solution: Repeat the welding with a compatible coupler
The welding cycle is interrupted whenever an