Measuring illuminance
To measure the
brightness of a continuous
light
source:
1. With
the film speed selector at
ASA 1
~O,
measuring-mode
set
for "AMB I",
and dis-
play indication
at " ExIN",
attach the op-
tional flat diffuser.
2.
Po
sition
the diffuser parallel
and as close
as
possible to
the surface where
light is to be
measured
and
push
the meter's
measuring
button
.
3. Read
the
value
indicated
and
work
it
through
the formula
below:
lux
=
2.5
X
2
'''·
Exampl
e
With
a
display
reading of
8.7,
work
the
equation as
follows:
lux
=
2.5
x
2
'·'
lux
=
2.5
x
415.9
=
1039
NO
T
E
For
precise measurement of
illumin
ance in
lux, use the
illuminance
meter.
Beleuchtu ngsstiirkemessu ng
Um die
Helligkeit
einer Dauerlichtquelle zu
messen,
verfah
ren Sie
wie
folgt.
1.
Stell
en
Si
e
den Filmempfindlichkeitswahler
auf
ASA
100,
den
Me~artenwahler
auf
"AMB
I"
und den Anzeigenartwahler auf
"ExIN".
Dann
befestigen
Sie
den
Plan-
Diffusor
(zusatzlich erhalt lich).
2. Den
Diffusor
parallel
und so nahe wie
mogliche
an
die Oberflache bringen, wo das
Licht gemessen werden
soli
.
Dann
drlicken
Sie die
Me~taste.
3
. Lesen Sie
den
angezeigten
Wert ab, und
setzen
Si
e
Lu
x
=
2.5
X
2
'''·
Lautet
die
Anzeige
beispielsweise
8.7,
rechnen Sie
fo
lgenderma
~en
.
Lux
=
2,5
x
2
'·'
=
2,5
x
415,9
=
1039
ANMERKUNG
Fur exakte Messungen in
Lu
x verwneden
Sie
einen Beleuchtungsstarkemesser.