Descargar Imprimir esta página

Porter Cable CPFC2TV3525VP-CA Manual De Instrucciones página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

Risk of unsafe operation. Compressed air from the unit may
contain wa ter condensation and oil mist. Do not spray un fil tered air at an item
that could be damaged by moisture. Some air tools and accessories may
require filtered air. Read the in struc tions for the air tools and accessories.
How to Start
1.
Turn the Auto/Off lever to "Auto" and allow tank pressure to build. Motor will
stop when tank pressure reaches "cut-out" pressure.
2.
Pull the regulator knob out and turn clockwise to increase pressure. When the
desired pressure is reached push knob in to lock in place.
Risk of unsafe operation. If any unusual noise or vibration is
noticed, stop the compressor immediately and have it checked by a trained service
technician.
The compressor is ready for use.
CUSTOMER RESPONSIBILITIES
Check Safety Valve
Drain Tank
Air Filter
Air compressor pump intake
and exhaust valves
1- more frequent in dusty or humid conditions
Risk of Unsafe Operation. Unit cycles automatically when
power is on. When servicing, you may be exposed to voltage sources, com-
pressed air, or moving parts. Before servicing unit unplug or disconnect elec-
trical supply to the air compressor, bleed tank of pressure, and allow the air
compressor to cool.
To ensure efficient operation and longer life of the air compressor, a routine mainte-
nance schedule should be prepared and followed. The above routine maintenance
schedule is geared to an air compressor in a normal working environment operating
on a daily basis. If necessary, the schedule should be modified to suit the condi-
tions under which your air compressor is used. The modifications will depend upon
the hours of operation and the working environment. Compressors in an extremely
dirty and/or hostile environment will require a greater frequency of all maintenance
checks.
NOTE: See Operation section for the location of controls.
TO CHECk SAFETY VALVE
Risk of Bursting. If the safety valve does not work properly,
over-pressurization may occur, causing air tank rupture or an explosion.
Risk from Flying Objects. Always wear certified safety equip-
ment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.
MAINTENANCE
Before
Daily
or after
each
each use
use
X
X
13 - ENG
Every 100
Yearly
hours
X
1
X
N015840

Publicidad

loading

Este manual también es adecuado para:

Cpfc2tv3525vp