Follow all valid standards and laws.
Ensure that the electrical connection meets the
requirements of the latest version of all applicable
standards and laws in the appropriate country, especially
the following standards: National Electrical Code, ANSI/
NFPA 70, or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No.0-M91.
Have a qualified electrical technician check the
grounding of the appliance.
Do not ground with a gas line.
No fuse protection in the neutral or grounding circuit.

Before you begin

Tools and parts needed

Saber Saw or Jig Saw
Drill
/
" Wood Drill Bit
1
4
Pliers
Phillips Screwdriver
Wire Stripper or Utility Knife
Metal Snips
Measuring Tape or Ruler
Level
Pencil
Caulking Gun
Duct Tape

Parts included

8
B e f o r e y o u b e g i n
Keep the installation instructions. Only connect the
appliance with a copper conductor. If possible, connect
the appliance to a metal cable guide directly to the fuse
box.
Ensure that the wire diameter meets the requirements of
the latest version of all applicable standards and laws in
the appropriate country, especially the following
standards: National Electrical Code, ANSI/NFPA 70, or
CSA Standards C22.1-94, Canadian Electrical Code, Part
1 and C22.2 No.0-M91.
Put a protecting hose that is listed in the U.L. or C.S.A. on
both ends of the connecting cable, that is, on the
appliance and on the fuse box.

Appliance dimensions

Safety clearances

WARNING
9
RISK OF FIRE
Grease deposits in the grease filter can catch fire.
The given safety clearance must be observed to
avoid heat buildup. Observe the specifications for
your cooking appliance. If gas and electric cooktops
are used together, the largest given clearance
applies.
The appliance may only be installed directly next to
a cabinet or wall on one side. The wall or cabinet
clearance must be at least 2" (50 mm).