Check the correct setting of the compressed air regulator. The pressure
regulator is in the fan component behind the service plate.
To do so, proceed as follows:
1. Switch off the product using the on/off switch and wait until the
illuminated ring on the on/off switch stops flashing completely.
2. Disconnect the product from the power supply by pulling out the mains
plug and secure against unintentional restarting.
3. Remove the rear service cover of the fan component.
4. If necessary, the pressure for the compressed air container must be
readjusted to 5 bar on the pressure regulator (Pos. 1).
5. Connect the product to the power supply and press the on/off switch to
put it back into operation. See also the chapter Commissioning.
7.2.4 Checking the compressed air container with
compressed air safety valve
NOTE
The product has one or more compressed air containers with
compressed air safety valve.
Products with compressed air container and safety valve must be
serviced/checked according to current national regulations.
1502828-04
Fig. 37: Setting the compressed air regulator
- 88 -