Cleaning The Spray Arms; Frost Precautions; Troubleshooting - Proline SDW 499 WH Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Cleaning the Spray Arms

The spray arms can be easily removed for periodic cleaning
of the nozzles, to prevent possible clogging.
To remove the upper and lower spray arms, hold and
unscrew or pull them out.
Wash the spray arms under running water and attach them
back in place, checking that the rotary movement is in no
way impeded.

Frost Precautions

Avoid placing the dishwasher in a location where the temperature is below 0°C. If this is
unavoidable, empty the dishwasher, close the door, disconnect the water inlet pipe and
empty it.

TROUBLESHOOTING

Problem
Possible Causes
Dishwasher
Fuse blown, or the
will not start.
circuit breaker
tripped
Power supply is not
turned on.
The door has not
been properly
closed.
Water not
Kink in drain hose
pumped from
Filter clogged
dishwasher
Kitchen sink clogged
Suds in the tub Improper detergent
Solutions
Replace fuse or reset circuit breaker.
Remove any other appliances sharing
the same circuit with the dishwasher.
Make sure the dishwasher is turned on
and the door is closed securely.
Make sure the power cord is properly
plugged into the wall socket.
Close the door securely.
Check drain hose.
Check the filters (see "Cleaning the Filter
Unit").
Check kitchen sink to make sure it is
draining well. If kitchen sink is not
draining, you may ask a plumber to
check it.
Use only the detergent special for
dishwasher to avoid suds. If this occurs,
open the door and let the suds
evaporate. Close the door securely then
start the soak wash cycle to drain the
water out. Repeat if necessary.