Urrea UD226 Manual De Usuario Y Garantía página 38

Multímetro automotriz básico
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E N G L I S H
rotary switch.
If a more accurate measurement is
desired, select the proper. Resistance range
using the RANGE button.
Insert:
• Black lead in COM jack.
• Red lead in RPM, V, Ω jack.
-Touch the test lead probes across the
resistance or circuit to be tested.
Accuracy:
Rapidly changing display readings (noise)
can sometimes be eliminated if you change
to a higher range.
Continuity Test.
A DMM with a continuity beeper allows
you to quickly and easily distinguish
between an open and a closed circuit.
The Meter beeps when it detects a closed
circuit or short, so you do not have to look
at the Meter during the test. This can be
a valuable troubleshooting aid when
determining: good or blown fuses and
fusible links, open or shorted conductors
and wires, the operation of switches, etc.
38
PARALLEL
CONTECTION
RED (+)
BLACK (+)
NOTE: Turn the power off to the circuit
to be tested. A beeper tone does not
necessarily mean zero resistance.
To test circuit continuity:
• Select the Ω /
switch and press the DC/AC button to
select the continuity (
The symbol
appears on the display and
the Meter defaults to the 400Ω range.
Insert:
• Black lead in COM jack.
• Red lead in RPM, V, Ω jack.
Connect one test probe to each end of the
circuit to be tested:
• If circuit is closed, the Meter will
beep @ < 100Ω
• If circuit is open, there is no beep.
RPM Measurements Using the
Inductive Pickup.
Pickup RPM refers to revolutions per
minute. Using the inductive pickup,
which comes with the Meter, RPM can be
CLOSED CIRCUIT
BEEPS SOUNDS
RED
(+)
BLACK
(-)
setting with the rotary
) range.

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido