Universal Realtime System Exclusive messages
Master Volume
status
data byte
F0H
7FH, 7FH, 04H, 01H, llH, mmH
Byte
Remarks
F0H
Exclusive status
7FH
ID number
7FH
device ID
04H
sub ID#1
01H
sub ID#2
llH
LSB of Master Volume
mmH
MSB of Master Volume
F7H
EOX
* LSB of Master Volume (llH) is processed as 00H.
Data Transmission
This instrument can use exclusive messages to exchange many varieties of internal settings
with other devices.
The model ID of the exclusive messages used by this instrument is 6AH.
Data Request 1 RQ1
This message requests the other device to transmit data. The address and size indicate the
type and amount of data that is requested.
When a Data Request message is received, if the device is in a state in which it is able to
transmit data, and if the address and size are appropriate, the requested data is transmitted
as a Data Set 1 (DT1) message. If the conditions are not met, nothing is transmitted.
status
data byte
F0H
41H, dev, 6AH, 11H, aaH, bbH,
ccH, ddH, ssH, ttH, uuH, vvH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number
dev
device ID
6AH
model ID
11H
command ID
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
ssH
size MSB
ttH
size
uuH
size
vvH
size LSB
sum
checksum
F7H
EOX
* The size of data that can be transmitted at one time is fixed for each type of data. and
data requests must be made with a fixed starting address and size. Refer to the address
and size given in "Mapa de direcciones de los parámetros" (p. 190).
* For the checksum, refer to (p. 204).
* This message is not received if the Rx.Exc parameter (SYSTEM/MIDI/SYS-EXC MIDI) is
OFF.
* This message is not received in GM mode.
status
F7H
(Universal Realtime message)
(Broadcast)
(Device Control Message)
(Master Volume)
(End Of Exclusive)
status
F7H
(Roland)
(dev: 10H - 1FH)
(XP-30)
(RQ1)
(End Of Exclusive)
Data Set 1
DT1
This message transmits the actual data, and is used when you wish to set the data of the
receiving device.
status
data byte
F0H
41H, dev, 6AH, 12H, aaH, bbH,
ccH, ddH, eeH, ... ffH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number
dev
device ID
6AH
model ID
12H
command ID
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
eeH
data:
:
:
ffH
data
sum
checksum
F7H
EOX
* The amount of data that is transmitted at one time is fixed for the type of data, and only
data of the fixed starting address and size will be transmitted. Refer to the address and
size given in "Mapa de direcciones de los parámetros" (p. 190).
* Data whose size is greater than 128 bytes should be divided into packets of 128 bytes or
less and transmitted. Successive ÒData Set 1Ó messages should have at least 20 ms of
time interval between them.
* For the checksum, refer to (p. 204).
* This message is not received if Rx.Exc parameter (SYSTEM/MIDI/SYS-EXC MIDI) is
OFF.
* This message is not received in GM mode.
This device is able to receive GS Exclusive messages only for Scale Tune settings.
Data Set 1
DT1
This message transmits the actual data, and is used when you wish to set the data of the
receiving device.
status
data byte
F0H
41H, dev, 42H, 12H, aaH, bbH,
ccH, ddH, ... eeH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number
dev
device ID
42H
model ID
12H
command ID
aaH
address MSB
bbH
address middle byte
ccH
address LSB
ddH
data:
:
:
eeH
data
sum
checksum
F7H
EOX
* This message is not received when the Rx.Exc parameter (SYSTEM/MIDI/SYS-EXC
MIDI) is OFF.
* This message is not received in GM mode.
Aplicación MIDI
status
F7H
(Roland)
(dev: 10H - 1FH)
(XP-30)
(DT1)
The actual data to be transmitted. Multi-byte
data is transmitted in the order of the address.
(End Of Exclusive)
status
F7H
(Roland)
(dev: 10H - 1FH)
(GS)
(DT1)
The actual data to be transmitted. Multi-byte
data is transmitted in the address order.
(End Of Exclusive)
187