Declaration Of Conformity - Samlex Europe PST-300S-12E Manual Del Propietário

Tabla de contenido

Publicidad

seCtIOn 12 |
SECTION 14 |
oUTPUT VoLTAGE
MAXIMUM oUTPUT CUrreNT
Responsible Party Name :
Responsible Party Name :
oUTPUT fREQUENCY
TYPE of oUTPUT WAVEfoRM
Address
Address
ToTAL HARMoNIC DISToRTIoN
of oUTPUT WAVeforM
CoNTINUoUS oUTPUT PoWer
(At Power factor = 1)
Phone No
Phone No
SURGE oUTPUT PoWER
PEAK EffICIENCY
Fax No
Fax No
AC oUTPUT CoNNeCTIoNS
Declares under our sole responsibility that the product
Declares under our sole responsibility that the product
NoMINAL DC INPUT VoLTAGE
DC INPUT VoLTAGE RANGE
MAXIMUM INPUT CUrreNT
Product Name
Product Name
DC INPUT CURRENT AT No LoAD
DC INPUT CoNNECTIoNS
DC INPUT fUSES (INTERNAL)
Model No.
Model No.
LoW DC INPUT VoLTAGE ALARM
LoWDCINPUTVoLTAGESHUTDoWN
to which this declaration relates is in conformity with the following standards or other
to which this declaration relates is in conformity with the following standards or other
HIGH DC INPUT VoLTAGE
normative documents
normative documents
SHoRT CIRCUIT SHUTDoWN
oVERLoAD SHUTDoWN
GRoUND fAULT SHUTDoWN
oVER TEMPERATURE SHUTDoWN
REVERSE PoLARITY oN
ReMote contRoL
WIRED REMoTE CoNTRoL WITH
LED / LED DISPLAY
WIRED oN / off CoNTRoL
foRCED AIR CooLING
Representative Person's Name : M van Veen
WoRKING ENVIRoNMENT
Signature
Signature
oPERATING TEMPERATURE RANGE
RELATIVE HUMIDITY
(W X D X H), MM
(W X D X H), INCHES
Date
Date
noteS:
1. All power ratings are specified for resistive load at Power Factor = 1.
2. All specifications given above are at ambient temperature of 25°C / 77°F.
3. Specifications are subject to change without notice
50
52 | SAMLEX AMERICA INC.
50 | SAMLEX AMERICA INC.
52 | SAMLEX AMERICA INC.
52 | SAMLEX AMERICA INC.
50
specifications
Declaration of Confirmity.

Declaration of Conformity

Declaration of Conformity
MoDeL no.
PSt-3000-12
oUtPUt
120 VAC ± 3%
25A
Samlex Europe B.V.
Samlex Europe B.V.
60 Hz ± 1%
Pure Sine Wave
:
Aris van Broekweg 15, 1507 BA ZAANDAM, The
:
Aris van Broekweg 15, 1507 BA ZAANDAM, The
< 3%
Netherlands
Netherlands
3000 Watts
:
+31-75-6704321
:
+31-75-6704321
6000 Watts (< 8 ms)
> 85%
:
+31-75-6175299
:
+31-75-6175299
NEMA5-20R GfCI Duplex out-
lets, Terminal Block for hard-
wiring
inPUt
12V
10.7 - 16.5 VDC
360A
:
DC -AC SINEWAVE INVERTER
:
DC-AC SINEWAVE INVERTER
< 1.6A
Bolt & Nut: 5/16" x 18 TPI
12 X 30A = 360A (Each Type
ATC, 32V, 30A)
DiSPLAY
PST-300S-12E, PST-300S-24E
:
:
LED
Power, overload, over Temperature
PRotectionS
10.7V ± 0.1V
10V ± 0.1V ; Auto-reset: 11.5V ± 0.3V
16.5V ; Auto-reset: < 16.5V
SHUTDoWN
output Voltage is 0V and ouput Current is 50A
EN 61000-4-2:2009 EN 61000-4-3:2006+A2: 2010 EN 61000-4-4:2012
EN 61000 -4 -2 :200 9 EN 61000 -4 -3 :2006+A2:
output Power = 3300W ± 50W (Power factor = 1) for 2 to 3 sec
only on GfCI outlets (5 to 6 mA leakage)
EN 61000-4-6:2009 EN 61000-4-8:2010
EN 61000 -4 -6:200 9 EN 61000 -4 -8 :2010
90°C ± 5°C (Sensed at Transformer T3); Autoreset at 65°C ± 5°C
External / internal DC sides fuses will blow
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
EN 60950 -1:2006+A11:2009+A1:2010+A12:2011
DC INPUT SIDE
EN55022 class B EN61000-3-2:2006+A2:2009 EN 61000-3-3:2008
EN55022 class B EN61000
RC-300 (sold separately) with 25' cable
(i) By switching external contact (ii) By switching external 12V/24V
signal
cooLinG
Temperature controlled fan (Sensed at Transformer T6)
fan oN at 55°C ± 3°C; fan off at 45°C ± 3°C
coMPLiAnce
:
Intertek - ETL Listed. Conforms to ANSI/UL Standard 458. and certi-
SAfETY
fied to CSA C22.2 No. 107.1-01
EMI / EMC
fCC Part 15(B), Class A
enViRonMent
:
:
-20˚C to 40˚C / -4˚f to 104˚f
Up to 85%, non condensing
DiMenSionS
263 x 456.5 x 145
10.35 x 17.97 x 5.71
: 18-11-2015
:
WeiGHt
KG
9.8
LBS
21.6
2010 EN
-3 -2:2006+A2:2009 EN 61000
EN55024:2010
EN55024:2010
M van Veen
18-11-2015
3
PSt-3000-24
120 VAC ± 3%
25A
60 Hz ± 1%
Pure Sine Wave
< 3%
3000 Watts
6000 Watts (< 8 ms)
> 88%
NEMA5-20R GfCI Duplex out-
lets, Terminal Block for hard-
wiring
24V
21.4 - 33 VDC
180A
< 1.0A
Bolt & Nut: 5/16" x 18 TPI
12 x 15A = 180A (Each Type ATC,
32V, 15A)
Power, overload, over Temperature
21.4V ± 0.2V
20V ± 0.2V ; Auto-reset: 23V ± 0.5V
33V ; Auto-reset: < 33V
61000 -4 -4:2012
-3 -3:2008
Indoor use
-20˚C to 40˚C / -4˚f to 104˚f
263 x 456.5 x 145
10.35 x 17.97 x 5.71
9.8
21.6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pst-300s-24e

Tabla de contenido