Anexo; Menú De Configuración Hart - Endress+Hauser Micropilot M FMR240 Manual De Instrucciones

Ocultar thumbs Ver también para Micropilot M FMR240:
Tabla de contenido

Publicidad

Anexo

basic setup
00
media type
001
liquid
solid
safety settings
01
output on alarm
MIN -10% 3.6mA
MAX 110% 22mA
hold
user specific
linearisation
04
level/ullage
level CU
ullage CU
level DU
ullage DU
extended calibr.
05
selection
mapping
common
extended map..
output
06
commun. address
envelope curve
0E
plot settings
envelope curve
env.curve+FAC
env.curve+cust.map
display
09
diagnostics
0A
present error
system parameter
0C
tag no.
¡Nota! Los valores por defecto de los parámetros están en negrita.
90
11
Anexo
11.1
Menú de configuración HART
tank shape
002
medium cond.
dome ceiling
unknown
horizontal cyl.
DK: < 1.9
DK: 1.9 ... 4
bypass
DK: 4 ... 10
stilling well
DK: > 10
flat ceiling
sphere
vessel / silo
00A
medium cond.
unknown
unknown
metal silo
DC: 1.6 ... 1.9
concrete silo
DC: 1.9 ... 2.5
bin / bunker
DC: 2.5 ... 4
dome
DC: 4 ... 7
stockpile
DC: > 7
conveyor belt
010
outp. echo loss
alarm
hold
ramp %MB/min
output on alarm
011
enter value
040
linearisation
041
040
manual
041
customer unit
semi-automatic
table on
horicontal cyl
customer unit
linear
customer unit
clear table
040
050
dist./meas value
008
check distance
D and L
distance = ok
are displayed
dist. too small
manual
dist. unknown
dist. too big
060
no. of preambels
061
low output limit
off
on
0E1
recording curve
0E2
single curve
cyclic
language
092
back to home
enter time
default: 100 s
0A0
previous error
0A1
clear last error
0C0
protocol+sw-no.
Micropilot M FMR240 4 a 20 mA HART
003
process cond.
004
empty calibr.
standard
enter value
calm surface
turb. surface
add. agitator
fast change
test: no filter
00B
process cond.
00C
empty calibr.
standard
enter value
fast change
slow change
test: no filter
012
delay time
in case of echo loss
max. 4000 sec.
default: 30 s
ramp %span/min
013
enter value
042
linearisation
next point
table no.
043
yes
input level
044
no
input volume
045
042
042
051
range of mapping
052
start mapping
input of
off
mapping range
on
pres. Map dist
054
cust. Tank map
is displayed
inactive
active
reset
062
curr. output mode
063
standard
fixed current
fixed cur. value
fixed current
4mA value
093
format display
094
no. of decimals
decimal
x
x.x
1/16"
x.xx
x.xxx
0A2
reset
0A3
unlock parameter
for reset code
for reset code
see manual
see manual
0C2
serial no.
005
full calibr.
006
enter value
005
full calibr.
006
enter value
014
045
053
055
064
068
20mA value
069
095
0A4
0C4
L00-FMR250xx-19-00-01-es-036
Endress+Hauser

Publicidad

Tabla de contenido
loading

Tabla de contenido