ABC2M-009_ES_FR_EN_PT_DE.book Page 46 Thursday, April 17, 2008 9:43 AM
INSTALLATION
General connections
M.D. Plug-in receiver for remote-control
ANT Reception antenna
SMF Plug-in receiver for traffic lights
SCA Lamp SCA (24Vdc)
AUX Power supply for peripherals (24Vac)
A.T. Control for full opening
S.EXT Exterior safety device (photocell or strip)
A.P. Control for pedestrian opening
S.INT Interior safety device (photocell or strip)
BAT Emergency battery (2x12V - 1.2Ah; parallel
connection))
Connection of the motors
Cable colours:
1
Motor coil connection (red wire)
2
Motor coil connection (blue wire)
3
Encoder signal connection (green wire)
4
Encoder power supply connection (-) (white wire)
5
Encoder power supply connection (+) (brown wire)
46
Installation manual
E1
Encoder motor 1
E2
Encoder motor 2
G1
Motor 1 rotation (24V)
G2
Motor 2 rotation (24V)
M1,2 Motors
EC
Electrolock (12Vac, 17Vdc)
SW1 General switch
RED
Control board power supply (230Vac, 50/60Hz)
L.G.
Garage light (230V, 2300W max)
DEST. Flashing lamp (230Vac, 60W max)
When connecting a single motor, do it in position
M1.