Tolerance
Temperature
coefficient
Test current
Low resistance
indication
Overvoltage
protection
Non contact voltage indication/electric field (NCV/EF)
(2100-Gamma only)
Voltage range
Frequency range
Indication
Data Hold
Measurement Area Illumination / Torch Light
General Specifications
Operation time
(DT)
Recovery time
Operating
temperature
Storage
temperature
Humidity
Operating
altitude
Safety rating
(overvoltage
category)
Pollution degree
Protection
degree
Safety
regulations
Approvals,
compliance
Power Supply
Power
consumption
Battery lifetime
Dimensions
(HxWxD)
Weight
± (5% rdg + 10 LSD) at 20°C
± (5 LSD / 10 K)
<30 μA
Acoustic indication <10...50 Ω
690 V AC/DC (2100-Alpha / 2100-Beta)
1000 VAC/1200 VDC (2100-Gamma)
100...1000 VAC
50...60 Hz
3 levels shown by LCD segments as
following:
2100-Beta: only voltage
measurement (12...690V AC/DC)
2100-Gamma: voltage and resistance
measurement, NCV
White LED
30 s
240 s
-15°C to +55°C
-15°C to +55°C
Max. 95% RH
Up to 2000 m
CAT IV / 600V, CAT III / 690V
(2100-Alpha / 2100-Beta)
CAT IV / 600V, CAT III / 1000V
(2100-Gamma)
2
IP 64
IEC 61243-3:2009,
EN 61243-3:2010,
DIN VDE 0682-401:2011
GS mark from TÜV Rheinland, CE
Battery 2 x 1.5V (AAA/ IEC LR03)
Approximately 60 mA
More than 10000 measurements
(<5 s / per measurement)
Approximately 280 x 78 x 35 mm
(11.0 x 3.1 x 1.4 in)
Approximately 320 g (0.71 lb)