How To Use Storage Area For "4Mm Ø Test Probe Extension; Specifications - Beha-Amprobe 2100-Alpha Manual Del Usuario

Ocultar thumbs Ver también para 2100-Alpha:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 76
W
Disconnect the voltage tester completely from any
measuring circuit first.
• Pull out the "GS 38 protective cap" 1 out of the "test
probe protector cover", place onto the test probe tips
2 and push firmly to secure it.
• For removal and storage 3 , please perform the
opposite operation.
How to use storage area for "4mm Ø test probe
extension":
4
5
W
Disconnect the voltage tester completely from any
measuring circuit first.
• To retrieve push the "test probe tip" into the "4mm Ø
test probe extension" 4 and twist right it approx.. ¼
turn 5 .
• Then pull on probe 6 to remove "4mm Ø test probe
extension" and continue twisting until "4mm Ø test
probe extension" is tight 7 .
• For removal please do the opposite way 8 and store
it as shown in last picture.

SPECIFICATIONS

Voltage Test
LED voltage range
LED indicator
LED tolerances
LCD voltage
range
LCD resolution
LCD tolerance
Frequency range
LED and LCD
response time
Acoustic indication ≥50 V AC, ≥120 V DC
Voltage detection Automatic (AC/DC)
Polarity detection Full range
Range detection
Current I
6
7
12...690 V AC/DC
(2100-Alpha / 2100-Beta)
12...≥690 V AC/DC (2100-Gamma)
±12, ±24, 50, 120, 230, 400, 690 V
(2100-Alpha / 2100-Beta)
±12, 24, 50, 120, 230, 400, ≥690 V
(2100-Gamma)
acc. to EN 61243-3:2010
12...690 V AC/DC (2100-Beta)
6...1000 VAC, 6...1200 VDC
(2100-Gamma)
1 V
± (3% rdg + 3 LSD)
DC, 16 2/3 Hz...400 Hz
<1s
Automatic
≤3.5 mA AC/DC at 690 V AC/DC
(2100-Alpha / 2100-Beta)
≤3.5 mAAC at 1000 VAC /
≤4.5 mADC at 1200 VDC
(2100-Gamma)
(load buttons not activated)
11
8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

2100-beta2100-gamma2100 serie

Tabla de contenido