6.4 Loading data
In dynamic operation, this must be considered for the design:
6.4.1 Loading data* Pipe system for linear units E, AE
Version
Length overall
in mm
RK pipe system linear
unit E18
RK pipe system linear
unit E80
RK pipe system linear
unit AE 30
RK pipe system linear
unit AE 40
RK pipe system linear
unit A/AS 30
RK pipe system linear
unit A/AS 40
RK pipe system linear
unit A/AS 50
RK pipe system linear
unit A/AS 60
Fx max = m*a [m/s2]
Permitted force (N)
Fx
Fy
500
500
1000
400
90
10
4500
5500
2300
500
–
–
1500
–
–
1500
–
–
1800
–
–
3000
–
–
4000
–
–
6. Product Information
Fz
1500
500
1000
–
60
8
550
5650
2500
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Permitted torque
(Nm)
Mx
My
1500
–
1,5
4
650
70
170
–
0,5
–
–
0,6
–
–
15
–
–
27
–
–
60
–
–
100
–
Mz
4
170
16
35
35
45
180
320
41