6. Product Information
6.4 Loading data
In dynamic operation, this must be considered for the design:
6.4.1 Loading data* Pipe system for linear unit E-II
Version
Length overall
in mm
RK pipe system
for linear unit E-II 30
RK pipe system
for linear unit E-II 40
RK pipe system
for linear unit E-II 50
RK pipe system
for linear unit E-II 60
* relative to the connected guidance slots (bending of guidance body f = 0,5 mm static, end ele-
ments supported)
Mx
Speed
Version
Bearings
Floating bea-
E-II
ring
E-II
Ball bearings
6.5 Emissions
The A-rated equivalent continuous sound pressure level of these linear units is below 85 dbA.
40
Fx max = m*a [m/s2].
Permitted force (N)
Fx
Fy
500
500
1000
800
500
60
1000
2100
250
1700
3000
600
2500
4500
1500
Fy
max. spindle speed
(r.p.m.)
80 rpm
250 rpm
Fz
1500
500
1000
10
500
50
60
1900
140
140
3000
600
380
4500
1300
Fz
My
Mz
Permitted torque
(Nm)
Mx
My
1500
9
6
15
50
14
40
140
30
65
320
45
120
Fx
Mz
15
40
65
120