uSer Menu
Set therMOStAt
The following menu allows (in models where provided) setting the room temperature for those products equipped with front
air fan. Once the set temperature is reached, the fan will set itself to the minimum.
The possible settings are: OFF - 06 ...40°C. The room temperature will be displayed alternately with the water temperature.
CONTROLS PROCEDURE
Press the key 6, Set cLOcK will appear.
Press key 2 several times until "uSer" is displayed
Press key 6.
"Set therMOStAt" will appear
Use keys 4-5 to select the room temperature.
Press key 6 to confirm and 1 to return to the menu
back to the initial status.
enAbLe fAn
This menu allows (in models where provided) enabling or disabling tangential motor operation
CONTROLS PROCEDURE
Press the key 6, Set cLOcK will appear.
Press key 2 several times until "uSer" is displayed
Press key 6.
"Set therMOStAt" will appear
Press key 2 until "enAbLe fAn" is displayed.
Use keys 4-5 to enable/disable ventilation.
Press key 6 to confirm and 1 to return to the menu
back to the initial status.
DiSPLAy
This menu allows to regulate the brightness of the display. The possible settings are from OFF - 10 to 31.
By activating OFF, the backlit display shall turn off after a set delay.
The backlight will turn on again upon pressing a button or when the machine enters in alarm mode.
CONTROLS PROCEDURE
Press the key 6, Set cLOcK will appear.
Press key 2 several times until "uSer" is displayed
Press key 6.
"Set therMOStAt" will appear
Press key 2 until "DiSPLAy" is displayed.
Use keys 4-5 to enable/disable ventilation brightness.
Press key 6 to confirm and 1 to return to the menu
back to the initial status.
PeLLet feeD ADJuStMent
The following menu allows the adjustment of pellet feed as a percentage.
If the stove has functioning problems owing to the quantity of pellets, adjust pellet feeding directly from the control board.
The problems correlated to the amount of fuel can be divided into 2 categories:
68
| engLiSh
1
OFF
1
2
OFF
3
6
4
5