8.
While holding down button 1, turn on the power.
The function test mode starts and "Self test" appears on the LCD.
9.
Press button 3 (
"Calibrate Label" appears on the LCD.
10. Press button 4 (
Paper sensor calibration starts.
11. "Online" will appear on the LCD if paper sensor calibration is successful.
If paper sensor calibration fails, an error message will appear on the LCD.
To load black mark paper
1.
Turn off the power.
2.
Pull the cover open lever forward and open the paper cover.
3.
Slide the paper damper stopper in the direction indicated by arrow A and release the
paper damper lock.
Lock the paper damper whenever you are using black mark label paper.
4.
Load the paper roll so that the printable side of the paper is facing down.
5.
Check to make sure the paper is above the paper damper.
6.
Adjust the paper position so no black mark is located under the black mark sensor.
Paper damper stopper
7.
Close the paper cover.
8.
While holding down button 1, turn on the power.
The function test mode starts and "Self test" appears on the LCD.
) five times.
).
Paper damper
Black mark
Roll paper
Black mark sensor
— 32 —
Black mark sensor
Label guide