VENTING REQUIREMENTS

WARNING:
MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney,
wall, ceiling, attic, crawlspace, or a concealed space of a
exhausting.
4" (102 mm) heavy metal exhaust vent
Only a 4" (102 mm) heavy metal exhaust vent and clamps
I
may be used. DURASAFE™ venting products are recommended.
Do not use plastic or metal foil vent.
I
Rigid metal vent:
Recommended for best drying performance and to avoid
I
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
I
Center location.
Remove excess to avoid sagging and kinking that may
I
I
I
I
overall vent system design as shown in the "Vent System Chart".
NOTE: If using an existing vent system, clean lint from entire length
of the system and make sure exhaust hood is not plugged with
metal vents. Review Vent System Chart and if necessary, modify
existing vent system to achieve best drying performance.
16
4"
(102 mm)
Exhaust hoods:
Must be at least 12" (305 mm) from ground or any object
I
or snow).
Do not use an exhaust hood with a magnetic latch.
I
Recommended Styles:
Louvered Hood
Acceptable Style:
Angled Hood
Elbows:
I
Recommended Styles:
Good
Clamps:
Use clamps to seal all joints.
I
Exhaust vent must not be connected or secured with screws
I
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
Vent products can be purchased from your dealer. For further
information, please call 1-800-4-MY-HOME
or visit our website at www.sears.com or www.sears.ca.
Box Hood
Better
®
(1-800-469-4663)