PLAN VENT SYSTEM
Recommended exhaust installations
Typical installations vent the dryer from the rear of the Laundry
Center. Other installations are possible.
A
B
C
A. Dryer
B. Rigid metal or flexible metal vent
C. Clamps
D. Wall
Optional exhaust installations
This Laundry Center can be converted to exhaust out the right or
left side. To convert the Laundry Center, use Side Exhaust Kit Part
Number 279823. If your Laundry Center was previously exhausted
from the right or left side, it can be converted to rear exhaust by
692790 (white)
3979370 (graphite)
3977784 (biscuit)
Follow the instructions in the kit to install. Kits are available from
your local Sears store or Sears Service Center.
A
A. Standard rear offset exhaust installation
B. Rear exhaust for offset close clearance connection
C. Left or right side exhaust installation
20
D
E
F
G
H
E. Elbow
F. Clamps
G. Elbow
H. Exhaust hood
B
C
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
Refer to the manufacturer's instructions provided with the vent
system.
A
A. Loop system with standard elbows
B. Loop system with one offset and one standard elbow
C. Vent system with one periscope (2" [51 mm] clearance)
NOTE: The following kits for close clearance alternate
installations are available for purchase. To order, please call
1-800-4-MY-HOME
(1-800-469-4663).
®
(For use with dryer vent
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
B
Less than 5" (127 mm)
5" (127 mm) to 18" (457 mm)
mismatch
18" (457 mm) to 29" (737 mm)
mismatch
29" (737 mm) to 50" (1.27 m)
mismatch
C