Installation - Pando E200/110 Instrucciones De Uso Y De Montaje

Ocultar thumbs Ver también para E200/110:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

INSTALLATION

E200/150 – E200/110 – E205/110 V1100
- E280/90.
Fit a false ceiling with an opening of the fol-
lowing sizes:
E200/150: 1465x965 mm with a minimum
distance of 270 mm between the ceiling and
the false ceiling;
E200/110: 1065x665 mm with a minimum
distance of 270 mm between the ceiling and
the false ceiling.
E205/110 V1100: 1065x665 mm with a
minimum distance of 270 mm between the
ceiling and the false ceiling.
E280/90: 865x405 mm with a minimum dis-
tance of 270 mm between the ceiling and the
false ceiling.
E215/110x70 1065mm.665mm. with a min-
imum distance of 190 mm between the ceil-
ing and the false ceiling.
(NOT valid for: E-215/110X70 model)
It is possible to select the side of the hood
where the air suctioned can be discharged.
After having chosen the most suitable posi-
tion, prepare the ducting: an air outlet con-
nection piece, with a diameter of 150 mm to
be installed in the side selected, is provided
with the appliance.
Special accessories of the same diameter are
supplied for Ø200mm motors.
Leave any unused exhaust outlets closed.
Draw the outline of the hole to house the
ceiling-mounted hood on the solid ceiling
(Fig. 1), according to the model chosen; make
4 holes in the ceiling according to the dimen-
sions shown in (Fig. 2); place the metric plugs
provided in the holes.
Open the stainless steel panels, following
the instructions mentioned in the USES sec-
tion, and remove the grease filters in order
to avoid damaging them in any way and too
allow installation (Fig. 3); screw the thread-
ed bars provided into the plugs (Fig.4); the
threaded bars are 250 mm long and serve to
install the ceiling-mounted hood at a dis-
tance from the solid ceiling of between 270
mm and 370 mm (Fig. 5); in case of a larger
gap between the hood and the ceiling, you
need to use longer threaded bars.
Make the electrical connections and connect
the air outlet pipe; place the ceiling-mounted
hood into the niche, by inserting the threaded
bars into the holes (Fig.6); the outer edge of
the hood needs to be perfectly flush with the
false ceiling. Insert the plates and nuts pro-
vided into the threaded bars, making sure to
tighten them securely (Fig. 7); refit the grease
filters and filter cover panels.
E200/150 – E200/110 – E205/110 V1100
WITH INTERNAL MOTOR
With Internal motor models, the same instal-
lation procedure as for the external motor
version (EM) can be followed, but with some
differences.
Remove the motor fixing screws ,pull the mo-
tor out, rotate it and then insert it in the out-
let hole just opened and fix it by using the
screws previously removed.
Unused holes must be closed with the suit-
able plug.
Carry out the installation as shown for the
external motor version, but taking into ac-
count the details above.
E210/150 V1350 – E210/110 V110 - E290/90
V1350 (internal motor)
Fit a false ceiling with an opening that has the
following dimensions:
E210/150 V1350: 1465x965 mm with a min-
imum distance of 330 mm between the ceil-
ing and the false ceiling;
E210/110 V1100: 1065x665 mm with a min-
imum distance of 330 mm between the ceil-
ing and the false ceiling
E290/90 V1350: 865x405 mm with a mini-
mum distance of 330 mm between the ceiling
and the false ceiling
It is possible to select the side of the cooker
hood where the air suctioned can be dis-
charged, as follows:
Remove the eight fixing screws of the suc-
tioning unit shown in fig. 11, pull the suc-
tioning unit out by disconnecting the electric
connector, remove the cover of the air out-let
hole you want to use and place the suction-
ing unit. Restore the electric connection and
secure the suctioning unit with the screws
previously removed. Refit the cover on the
27

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido