unused air out-let hole. Carry out the in-
stallation following the procedure shown for
E200/150, E200/110 and E280/90 models.
E210/150 V1350 – E210/110 V1350 WITH
EXTERNAL MOTOR
Fit a false ceiling with an opening that has the
following dimensions:
E210/150 V1350: 1465x965 mm with a min-
imum distance of 330 mm between the ceil-
ing and the false ceiling;
E210/110 V1350: 1065x665 mm with a mini-
mum distance of 330 mm between the ceiling
and the false ceiling.
It is possible to select the side of the cooker
hood where the air suctioned can be dis-
charged, as follows:
Remove the eight fixing screws of the air-
outlet flange shown in fig. 12, and place the
suctioning unit on the desired side where the
cover was previously removed. Refit the cover
on the unused air out-let hole. Carry out the
installation following the procedure shown
for E200/150 and E200/110 models.
ATTENTION! For versions with V1800 or
V2300 external motors, take great care
when connecting the cable of the motor to
a central unit of the circuit. Extract a con-
nection terminal from the central unit (re-
fer to the attached image).
These motors have two connectors; one is
6-way and the other 2-way. Before con-
necting the 2-way connector, extract a ter-
minal from the central unit, otherwise the
motor will not function correctly.
28