GB.7.2.3 Exhaust Filter
The exhaust fi lter is designed to primarily fi lter the carbon
dust from the carbon brushes of the motor.
It is situated on the top of the machine, in the front of the cover
below the handle. Pull the fi lter outwards by fi rmly holding
onto the black plastic tab/handle. Open the fi lter gate/frame
which now exposes the fi lter fl eece. Replace the fl eece, close
the frame and reinsert it into the machine. The exhaust fi lter
should be changed at least every six months.
GB.7.3 Changing the power cable
The high quality power cable (HAR - H05VV-F approved)
has conductor cross sectional areas of 1 sq. mm and these
conductors are made up of many single strands. A damaged
cable can be easily replaced. To remove the power cable,
simply push the spring-loaded plug-retaining pin downward
and pull out the cable plug. Insert the new power cable plug
and release the pin to secure the plug in position.
For safety reasons only, genuine Tennant spare parts
should be used! Any unauthorized opening of the appliance,
technical modifi cations or non-original parts will annul the
guarantee!
GB.7.4 Spares and accessories
Should you require spares, accessories or consumables for
your Tennant V5 please contact your Tennant distributor.
Please dispose of packaging in an environmentally
friendly manner
The packaging materials can be recycled. Please
do not dispose of the packaging with domestic
refuse but have it recycled.
Please dispose of old units in an environmentally friendly
manner
Old units contain valuable recyclable materials
which should be reclaimed. Batteries, oil and similar
substances must not pollute the environment.
Please therefore dispose of old units via suitable
collection systems.
Technical data
Description
Voltage
Frequency
Rated Power
Depression
Air Flow
Height
Length
Width
Dust Capacity of Bag
Sound level
Mass (without accessories)
1)
EN 60704-1 (1996)
EN 60704-2-1 (2000)
ISO 3744 (1994)
Tennant V5
V
220-240
Hz/-
50/60
W
1000
mbar (max)
220
l/s (max)
48
mm
350
mm
400
mm
340
l
8
1
dB(A)
58
kg
5.5
7

Publicidad

loading

Este manual también es adecuado para:

Mv52074