g. 16
G
I
G
*
g. 17
g. 18
INSTALLATION
B
A
A
*
*
H
B
A
FUME DISCHARGE (STEEL VERSION)
The STEEL version of ARIS is con gured for connecting the
fume discharge pipe to the rear and to the top.
WHATEVER SOLUTION IS USED TO CONNECT THE
FUME OUTLET TO THE FLUE, IT IS NECESSARY TO
REMOVE THE LEFT-HAND REAR METAL SIDE (A -
Fig. 16-18) AND THE LEFT-HAND METAL SIDE (B - Fig.
16-18).
NB: add silicone (provided) between the fume volute inlet and
the elbow union provided (for fume discharge from top), or to
the pipe section provided (for fume discharge from rear).
FUME DISCHARGE FROM REAR
Remove the lower rear portion (G - Fig. 16).
Remove the pre-cut section
removed lower rear portion (G) and from the left-hand rear
metal side (A).
Remove the pre-cut section (I - Fig. 17) from the stove struc-
ture.
Connect the ue section (H - Fig. 17, provided) onto the fume
volute inlet using the clamp provided.
FUME DISCHARGE FROM TOP
Mount the elbow union suing the clamp (L - Fig. 19) provided
onto the fume volute inlet.
Remove the cover on top (Q - Fig. 19).
Connect the fume discharge pipe (not provided) to the afore-
mentioned elbow union (Fig. 19).
Insert the rose (U - Fig. 19) provided.
AFTER CONNECTING THE FUME DISCHARGE PIPE
TO THE FLUE, RE-ATTACH THE LEFT-HAND REAR
METAL SIDE (A) AND THE LEFT-HAND METAL SIDE
(B).
Q
g. 19
- 42
-
*
(Fig. 17) from the previously
U
L