Electrical Characteristics; Safety Devices - EdilKamin ARIS Instalación Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
THERMO TECHNICAL CHARACTERISTICS
Thermal power output
Yield / Ef ciency
Emissions CO 13% O
2
Fume temperature
Fuel consumption
Hopper capacity
Draught
Autonomy
Heatable volume *
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
Weight including packaging (steel/ceramic/ollare stone)
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Thermal power output
Temperature of fumes on exit from the discharge pipe
Minimum draught
Fume ow capacity
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.

ELECTRICAL CHARACTERISTICS

Power supply
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by quali ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a UPS of at least 800
Vac. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certi cation on the part of the noti ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.

SAFETY DEVICES

• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on de ned parameters.
• VACUUM GAUGE:
Positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
GENERAL INFORMATION
according to EN 14785 (for other values, see DoP on page 35)
Nominal power
8
90,1
0,019
174
1,8
15
12 - 5
7
210
80
40
165/184/189
Nominal power
8
209
0-5
5,4
230 Vac +/- 10% 50 Hz
120 - 150 W
400 W
2,4 GHz
T2A, 250 Vac, 5x20 Fuse
- 34
-
Reduced power
2,4
kW
94,67
%
0,035
%
81
°C
0,5
kg/h
kg
10 - 3
Pa
24
hours
3
m
mm
mm
kg
Reduced power
2,4
kW
97
°C
Pa
2,4
g/s

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aris plus

Tabla de contenido