RIB SUPER 6000 Manual De Instrucciones página 31

Ocultar thumbs Ver también para SUPER 6000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

A - CONNEXIONS
IT IS COMPULSORY TO SET THE
DIP 13 OF THE CONTROL PANEL
IN THE ON POSITION.
T1
T2
T T R
S
T
N
U
JA
3-PHASE LINE
400V + N
MOTOR
3 P
J1
L1 - N
230Vac 50/60Hz POWER SUPPLY
BLINKER (40 W MAX.)
J2
U-V-W
CONNECTION TO JC CONTACTS OF THE CARD R2
J3
PED. BUTT.
PEDESTRIAN OPENING CONTACT (NO)
A+ TEST
+24Vdc SAFETY STRIP SELF-TEST POWER SUPPLY
LSC
CLOSE LIMIT SWITCH THAT CUTS OFF THE MOTOR IN CLOSING
COM
LIMIT SWITCH COMMON CONTACT
LSO
OPEN LIMIT SWITCH THAT CUTS OFF THE MOTOR IN OPENING
J4
STOP
STOP CONTACT (NC)
OPEN
OPENING CONTACT (NC)
CLOSE
CLOSING CONTACT (NC)
K. BUTT.
SINGLE PULSE CONTACT (NO)
A+
ACCESSORIES POWER SUPPLY +24Vdc
A-
ACCESSORIES POWER SUPPLY -24Vdc
SIGNAL
GATE OPEN INDICATOR 24Vdc
COM
COMMON CONTACT (common line for all the command and
safety inputs)
EDGE NC
SAFETY STRIP CONTACT (NC)
J5
AERIAL
RADIO ANTENNA
COM
COMMON CONTACT (common line for all the command and
safety inputs)
PHOTO NC
PHOTOCELLS CONTACT (NC)
S3
J5
TR1
TR2
J4
J3
J2
V
W
J1
PTO
J7
J6
SW
RADIO
J8
SW1
SW2
SW3
SW
S1
J6
PROBE
IS NOT AVAILABLE
J7
ENCODER
IS NOT AVAILABLE
J8
RADIO
CONNECTOR FOR EXTERNAL RADIO RECEIVER 24Vdc
S3
PROG.
PROGRAMMING BUTTON
TR1
LOW SPEED
IS NOT AVAILABLE
TR2
TORQUE
IS NOT AVAILABLE
SW
(only CRX control board) DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
RADIO
SW S1
DO NOT REMOVE THE JUMPER! OTHERWISE THE OPERATOR
WILL NOT WORK!
SW1
DIP-SWITCHES
SW2
SW3
CARD R2
T1 - T2 T
POWER RELAYS FOR THE COMMAND OF THE MOTOR
JA
R-N
SINGLE PHASE POWER SUPPLY - NEUTRAL
CONTACTS FOR THE EARTH CONECTION
U-V-W
MOTOR CONNECTION
31
INNER THERMAL OVERLOAD CUT-OUT
SWITCHES (per CEI 2-3/IEC 34-1)
The electrical protections on the SUPER 6000
motor power line may not be sufficient to protect
against overloads. If the cooling conditions worsen,
the motor overheats but the electrical conditions
do not change, which inhibits line protections.
Installing the bimetallic device PTO on the
S1-CRX/R4 control panel solves this problem.
This is a normally-closed electromechanical device
that opens when the threshold
temperature is reached; it
automatically resets when the
temperature falls below the
threshold level.
T
NC: NORMALLY CLOSED CONTACT
NO: NORMALLY OPEN CONTACT
G
B
T

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

S1-crx/r4

Tabla de contenido